Slim design and completely hidden under the ceiling for a luxurious beauty
Mitsubishi Heavy duct connected inverter air conditioning FDUM100VF2/FDC90VNP (9.0kW) - Low/Middle Static pressure has a thin design. The height is only 280mm, this product has many advanced designs that bring the most comfort and convenience to users. Using the inverter system to save electricity, the inverter and the R410A Refrigerant line are environmentally safe.
High Efficiency cooling / heating capacity
A 2-way air conditioning with 9.0 kW cooling capacity and a 9.0 kW heating capacity for a room area of 40 - 45m2 for optimum performance is the Mitsubishi Heavy FDUM100VF2 Inverter.
Automatic External Static Pressure (E.S.P.) Control
Mitsubishi Heavy duct connected air conditioning FDUM100VF2/FDC90VNP inverter (4.0Hp) - 9.0kW can set required E.S.P by E.S.P. button in the wired remote controller.
The outdoor unit is compact
Employment of lead-free solder - Adapted to RoHS directive, environmental protection
Avoid environmental pollution for the globe, all types of our products have been applied lead-free solder alloy materials in production. Six types of toxic chemicals that we do not use, including Pb, Hg, Cd, Cr6 +, PBB, PBDE applied to the RoHS standard in European (EU) markets from July 1 / 2006.
In Vietnam, according to Circular No. 30/2011 / TT-BCT dated 10/08/2011 regulating the permissible content limit of hazardous chemicals in electrical, electronic products and the attached Appendix for s types of chemicals above. Mitsubishi Heavy Industries factory has applied the RoHS standard does not use six toxic chemicals equivalent to IEC 62321 standard according to Decision No. 4693 / QD-BCT (amended Circular No. 30/2011 / TT-BCT) for All products of Mitsubishi Heavy Industries brand air conditioners in the Vietnamese market.
Seer & SCOP high efficiency
Although the nominal efficiency is lower than that of the Hyper Inverter type, it has achieved by SEER & SCOP higher by optimal control.
Easy Transportation and Installation
New inverter control (vector control)
The new inverter control technology based on vector control technology, thus providing the highest operating efficiency.
- Quiet operation from low speed to high speed.
- Achieve smooth sinusoidal voltage fluctuations.
- Significantly improved energy efficiency in the low-speed range.
Improvement of the Serviceability
Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance can be carried out from the right side or the bottom side of the unit.
Enhanced Installation Workability
600mm Drain Pump is mounted in all models. The indoor unit is completely hidden in the ceiling, so this is suitable for spaces with classy interior decoration.
Transparent Inspection Window
Dirt condition of the bottom of a drain pan can be checked through this transparent inspection window without removing drain pan.
Specifications
Powerful-Hi mode selected
Noise level: 125VSAPVF 36dB (A), 140VSAPVF1 38dB (A), 200VSAPVF2 44dB (A), 250VSAPVF 45dB (A), 140VSTVF 37dB (A), 200VSATVF1 38dB (A), 71VNPVF1 38dB (A), 90VNPVF2 44dB (A), 90VNPVF2 44dB (A) ,
100VNP1VF2 44dB (A)
Air flow: 125VSAPVF 20m3 / min, 140VSAPVF1 24m3 / min, 200VSAPVF2 36m3 / min, 250VSAPVF 39m3/ min, 140VSTVF 13m3 / min, 200VSATVF1 24m3 / min, 71VNPVF1 24m3 / min, 90VN PVF2 36m3 / min, 100VNP1VF2 36m3 / min
Note:
Parameters measured under conditions (IOS-T1)
Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. by 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.
* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions
** Indicators only apply when operating one indoor unit
*** Static pressure can be changed by setting on the controller. The maximum static pressure is set to "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa
**** If a cooling operation carries out when the outdoor temperature is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the low pressure will slip off, and the compressor frequency will increase, which reduces the capacity and can lead to damage.