Table of contents
The inverter technology saves energy in the long term, reducing electricity bills is significant
Did you know the compressor is the part that generates the most noise and consumes the most power in an air conditioner because it is the part responsible for compressing and circulating refrigerant?
Manufacturers of inverter air conditioners based on traditional rotary compressors that operate according to the up and down spring movement, Daikin uses a unique Swing compressor for Inverter technology.
The swing compressor has a monolithic design, gentle circular motion to significantly reduce friction and vibration during operation, no refrigerant leakage when in use.
As a result, Swing compressors help save costs and quieter operation. Specifically, INVERTER makes long-term savings. At the same time, improving the noise level of both outdoor and indoor units helps the machine operate quietly, maintain a stable temperature and achieve optimum capacity.
The Daikin FTKA35UAVMV (1.5 Hp) Inverter Air Conditioner will increase power to reach the right temp. The machine remains free of power waste at steady temperatures and considerable saving power if the ambient temperature is close to the set temperature.
Fast cooling capacity, saving energy
Daikin FTKA35UAVMV has a cooling capacity of 12.000 Btu/h (suitable for rooms with an area 16 - 20 m² or 48 - 60 m³).
With a power consumption of 0.96 kW and an energy efficiency index of CSPF to 5.01, it helps to minimize the cost of electricity bills for the family each month.
Comfort airflow Coanda
Unique design of Coanda panel brings the airflow along the ceiling, to spread out across the whole room without creating uncomfortable drafts directly o the body, bring maximum comfort
This design applies from the scientific Coanda phenomenon, causing the cold air emanating from the mouth of the wind to be pushed up to the ceiling and then gently radiate down, covering the entire room.
This delicate design helps the Daikin air conditioner bring comfort to users, do not blowing air directly into the area, but distributing fresh air evenly throughout the room for all users in the room.
Hi-low Voltage Shield
This feature includes a high-strength electronic circuit installed in the outdoor unit.
When the voltage fluctuates abnormally, this circuit protects the fan motor and compressor without the need to install a voltage stabilizer.
Specifically, in the voltage range from 150-264V: the machine works normally. Over 264-440V: the air conditioner will stop by itself, disconnect the power to prevent damage.
Notes: applied with 1 phase electricity
Air Purification
Enzyme Blue Filter (Option)
Deodorizes and catches the allergens, bring the fresh air to your house.
PM2.5 Filter (Option)
This filter removes PM 2.5, particulate matter which is smaller than 2.5 micrometres (µm).
Mould-Proof Operation
When cooling operation is stopped, fan-only operation runs automatically for one hour. This airflow dries the inside of the indoor unit to prevent the generation of mould and odours, strengthen durability of air conditioner.
Anti-corrosion Treatment of Outdoor Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are processed using a special anti-corrosion treatment: coated with two electrostatic coatings, the surface is covered with a thin acrylic resin layer to provide enhanced resistance to acid rain and salt corrosion.
FTKA35UAVMV Inverter Daikin’s printed circuit boards are specially strengthened durablity to withstand voltage fluctuations upto 440V. (Notes: applied with 1 phase electricity)
Using gas R-32 is environmentally friendly
Daikin FTKA25UAVMV air conditioner uses ozone layer (ODP) non-destructive refrigerant R-32, and the global warming index (GWP) is only 1/3 of that of R-410A and R-22.
Remote control Manual
Specifications
Note: The above values are based on operation with 220V, 50Hz.
Measurement conditions
1. Capacity based on: indoor temp. 27 ° CDB, 19 ° CWB; outdoor temperature 35 ° CDB tube length 7.5m.
2. The noise level is based on the above temperature 1 condition, which is an anechoic conversion value. These values may be slightly higher in fortune
actual practice due to the impact of ambient conditions.
3. CSPF is based on TCVN 7830: 2015.
Highlights
Power-Airflow Flap
The Power-Airflow Flap flattens out during cooling operation to deliver cool air to the corners of a room. The flap also directs warm air straight down to the floor during heating operation.
Vertical Auto-Swing (up and down)
This function automatically moves the flaps up and down to distribute air across a room.
Wide-Angle Louvers
The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room.
Airflow Coanda
Unique design of Coanda panel brings the airflow along the ceiling, to spread out across the whole room without creating uncomfortable drafts directly o the body.
Indoor Unit Quiet Operation
Indoor unit operating sound pressure levels are decreased from the Low setting fan speed using the wireless remote controller.
Auto Fan Speed
The microprocessor automatically adjusts the fan speed to high to rapidly reach the set temperature. Once the temperature is achieved, this function reduces the fan speed to low.
Programme Dry Function
The computer chip works to rid the room of humidity while keeping the room temperature as stable as possible. It controls the temperature and airflow rate automatically, so manual adjustment of these functions is not available.
Removable Drain Pan
The drain pan collects condensation from the indoor heat exchanger fins. Removable drain pans help to reduce the cleaning time and ensure a perfect finish.
Wipe-Clean Flat Panel
The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning
Dust Collection Filter (PM 2.5) (optional accessory)
This filter removes PM 2.5, particulate matter which is smaller than 2.5 micrometres (µm).
Mould-Proof Air Filter
When cooling operation is stopped, fan-only operation runs automatically for one hour. This airflow dries the inside of the indoor unit to prevent the generation of mould and odours, strengthen durability of air conditioner.
Enzyme Blue Filter (Option)
Deodorizes and catches the allergens, bring the fresh air to your house.
Standby Electricity Saving
Even when an air conditioner is not operating, it requires standby power. However, thanks to this function, the required standby power can be reduced.
Econo Mode
This mode limits the maximum power consumption. It improves operating efficiency and also prevents circuit breakers from being overloaded.
Inverter Powerful Operation
This function boosts cooling performance for a 20 minute period. It is convenient when it is necessary to change the room temperature quickly.
New generation refrigerant R-32
To cope with climate change, Daikin has used R-32 - New generation refrigerant, which does not cause ozone depletion and has a low global warming index.
Smartphone Control (Optional)
Smartphone control: by adding a WLAN device, you can set the temperature and schedule the air conditioner anywhere, using an Apple or Android ™ device.
Indoor Unit On/Off Switch
The unit can be conveniently started by hand if the wireless remote controller is misplaced or its batteries are not charged.
Count Up-Down On/Off Timer
The operation start and stop times can be set with the touch of a single button and preset for a period of one to 12 hours in one hour increments. When the off timer is set, Night Set Mode is activated automatically.
Night Set Mode
Pressing the off timer button automatically selects Night Set Mode. This function prevents excessive cooling or heating for a pleasant sleep. After 60 minutes, the room temperature is raised by 0.5˚C for cooling operation or lowered by 2˚C for heating operation.
Auto-Restart after Power Failure
The air conditioner memorises the settings for operation mode (automatic, cooling, heating, dry and fan only), airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.
Self-Diagnosis with Digital Display
Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.
Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion.
Low/High Voltage Shield
The product equips with a highly durable electronic circuit that can withstand voltages up to 440V.
(*) FTKA's operating voltage is from 150V-264V. Notes: applied with 1 phase electricity