Table of contents
Inverter one-way
Specially designed for shops, restaurants, and small offices, the SkyAir inverter series meets all customer needs thanks to a diversity of indoor units and power supplies.
- Inverter technology.
- Diverse indoor units.
- Outdoor heat sink fins are treating against corrosion.
- Easy-to-use remote navigation control, Weekly Schedule feature.
Ceiling suspended indoor unit
Comfortable airflow travels throughout the room
- The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation.
- Sophisticated design.
- Quite operation.
- Installation flexibility.
- Easy maintenance.
Latest model with modern design
- Sophisticated design.
- Latest model with modern style.
- Flap neatly closes when not in use.
- White colour.
Comfort
The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation.
Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room.
Louver manually adjusts for straight or wide angle airflow.
Suitable for high ceilings.
Two selectable temperature sensors.
Variable fan speed: High / Medium / Low.
Mode "Dehumidification".
Installation Flexibility for Freedom of Design
The unit fits more snugly into tight spaces.
Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening.
DIII-NET communication standard: Connection to a centralised control system is available without need for an optional adaptor.
All wiring and internal servicing can be done from under the unit.
Easier piping work for rear side by removable frame.
Easy Maintenance
Drain pump kit (option) includes a silver ion antibacterial agent: That assists in preventing the growth of slime, bacteria, and mould that cause odours and clogging.
Non-flocking flap. Condensation does not easily form and dirt does not cling to non-flocking flap. It is easy to clean.
Easy-clean, flat surfaces. It is easy to wipe dirt off the flat side and lower surfaces of the unit.
Quiet Operation
Oil Resistant Grille
Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments.
High CSPF inverter technology
Thanks to the combination of energy-saving technologies, the product's CSPF achieves between 4.85 and 6.47.
Compact outdoor unit, save space
The latest outdoor unit is more compact, with just 990mm in height than the previous non-inverter edition. Easy to deploy and sustain high CSPF energy-saving efficiency in confined spaces.
Outdoor heat sink fins are treating against corrosion
The heat exchanger corrosion-treated (acrylic pretreated) is used to increase reliability by increasing resistance to salt corrosion and air emissions for the outdoor heat exchanger.
Easy-to-use remote navigation control with Weekly Schedule feature
Ability to quickly cool and dehumidify the air: New inverter technology gives comfort more quickly (One-way cooling)
Quick cooling function: Quickly and easily make space comfortable before the arrival of office workers or shop customers. As well as quick cooling at maximum capacity, new inverter control rapidly removes indoor humidity. More than simple temperature reduction, this twin reduction provides greater comfort (within a maximum of 30 minutes).
Why is inverter technology economical?
Inverter system consumes less electricity, and soon recovers the difference in initial cost. This results in lower total cost.
Inverter air conditioner can adjust its cooling capacity according to the cooling load. This results in less power consumption.
In response to fluctuating cooling load, Non inverter air conditioners repeatedly perform ON (full-power) / OFF (zero-power) operation. Inverter air conditioners, however, operate at optimal cooling capacity according to the cooling load. Since inverter air conditioners provide required minimum cooling capacity with minimum electrical power, total power consumption can be reduced during cooling period.
Inverters operate without repeated ON/OFF operation.
Why is inverter technology more comfortable?
When temperature does not fluctuate much, the set temperature is maintained. Inverter control responds to load changes and causes minor temperature adjustments. Non-inverter control frequently turns ON and OFF in response to load fluctuations or load mismatch and causes large temperature swings.
Other convenient functions: Better still,... Advanced Daikin inverter technology brings many different benefits to customers and installers.
Automatic protection against low voltage: In AM and PM peak electricity consumption periods, supply may fluctuate. Built-in low-voltage protection will automatically cut operations. When normal voltage is restored, operation will resume as before.
Coated printed circuit boards: Coated circuit boards prevent problems caused by humidity and airborne dust. It also protects against salt contained in sea breezes. Both sides of the PCB in outdoor units are coated.
Self-diagnosis functions enable prompt maintenance response: An error message appears on the LCD of the remote controller and an LED lights up on the unit. When the BRC1E62 is installed, the error code appears showing contact information and model name. Contact your Daikin dealer and provide the error code and model name.
The BRC1E62 remote controller includes convenient functions
Setpoint auto reset
- Even if the set temperature is changed, the new set temperature returns to the previous preset value after a preset duration of time.
- Period selectable from 30, 60, 90, or 120 min.
Setpoint range set
- Saves energy by limiting the min. and max. set temperature.
- Avoids excessive heating or cooling.
- This function is convenient if the remote controller is installed where anyone can change the settings.
Night quiet operation mode
Consideration is given for people living nearby. Outdoor unit operating sound can be reduced.
Technology
Advanced technology, including the use of corrosion resistant electronic expansion valves, acid neutralisers and improved compressor reliability, enables the re-use of existing piping* without the need of pipe flushing for a simplified replacement process.
Specifications
Note:
- Rated cooling capacities are base on the following conditions: Room temperature 27 ° CDB, 19 ° CWB; outdoor temperature 35 ° CDB, 24 ° CWB; 7.5 m equivalent refrigerant piping (horizontal)
- Capacity is net value, including the deduction of heat from an indoor engine.
- Value converted under anechoic chamber conditions. If measured under actual installation conditions, the actual value is usually higher than the specification due to ambient noise and acoustical echo.
BACKGROUND DAIKIN SKYAIR INVERTER SAVE ELECTRICITY FOR BUSINESS